Archive for October 29, 2023

TSP #273 – QuantAsylum QA403 24-bit, 0.0001% THD Audio Analyzer Review, Teardown & Experiments

In this episode Shahriar takes a detailed look at the QuantAsylum QA403 24-bit, extraordinary linear & low-noise audio analyzer. This low-cost instrument provides the means to test a wide range devices in the audio frequency range:

https://quantasylum.com/collections/frontpage/products/qa403-audio-analyzer

The review of the instrument is organized as follows:

00:00 – Introduction, instrument interfaces and overview
01:03 – Detailed teardown, architecture overview, ADC, DAC, amplifiers, attenuators and interface challenges; isolated properties, THD and SNR considerations
10:14 – Instrument extreme performance verification through loop-back; detailed GUI overview, ADC & DAC operations, attenuators, THD measurements, built-in generators and measurement functions
22:47 – Stanford Research Systems (SRS) DS360 Ultra Low Distortion Generator performance verification using the QA403
25:28 – Characterization of the SRS SR560 Low-Noise Preamplifier, linearity, THD+N, low-pass and high-pass filters responses, low-noise versus dynamic reserve measurements, automated sweeps
35:40 – Characterization of a two-stage audio amplifier and headphone driver module; gain and THD variation measurements as a function of frequency
38:55 – QuantAsylum family of products, example measurements and additional resources
39:27 – Concluding remarks

Please consider supporting The Signal Path:
https://www.TheSignalPath.com/Donate
https://www.Patreon.com/TheSignalPath

Other links:
https://www.TheSignalPath.com
https://www.Twitter.com/TheSignalPath

TSP #272 – How good is an $85, 10GHz Power Sensor? Detailed Teardown, Analysis & Experiments

In this episode Shahriar takes a look at an inexpensive power sensor module with built-in battery and a tiny LCD screen. The instrument claims a large dynamic range of -60dBm to +30dBm!
A leaky internal battery prevents the unit form powering on initially. After analysis of the chemical leakage (using an Agilent Resolve Raman) as well as repair of the battery, the unit return to normal operation. A detailed teardown of the sensor is presented along with the theory of operation for the front-end RF circuits and sub-components. The unit is then measured against a R&S 3-Diode Path NRP power sensor. Although it does not perform nearly as well, it can be used within +/-2dBm accuracy. The unit is then measured against its highest claimed frequency of operation and input power.

Please consider supporting The Signal Path:
https://www.TheSignalPath.com/Donate
https://www.Patreon.com/TheSignalPath

Other links:
https://www.TheSignalPath.com
https://www.Twitter.com/TheSignalPath