Archive for July 31, 2022

TSP #229 – Going off-grid! BigBattery RHINO 48V, 14kWh LiFePO4 Battery Review & Experiments

In this episode Shahriar takes The Signal Path Lab off-grid! The BigBattery RHINO 48V LiFePO4, 276Ah, 14kWh is combined with a Growatt SPF 6000T inverter to provide 240V split-phase power to the house.

You can see the kit used in this video using this untracked, direct link to BigBattery.com:

https://bigbattery.com/products/48v-off-grid-home-rhino-system/

The review of the battery is organized as follows:

00:00 – Introductions & considerations.
01:33 – BigBattery offerings, battery configurations, battery chemistry, specifications, warranty, etc.
05:51 – Battery construction quality, connector & fuse design, mobile cart, attachment options.
07:50 – Provided battery cable with Anderson connector, ratings, quality.
08:14 – Built-in LCD screen, GUI & BMS access from the battery, phone app & BMS configuration.
11:36 – Battery protection, BMS under small loads, BMS disconnect behavior, power reporting.
16:08 – Off-grid setup, Growatt inverter wiring & interfaces, transfer switch & AC access.
18:28 – Benefits of a boiler setup for battery backup operation.
18:59 – Ensuring correct earth-ground & neutral wiring of the backup system.
19:52 – Going off-grid! House power measurements, battery discharge behavior.
21:27 – Battery charging behavior, balancing, charging battery to maximum level, charge waveform.
22:44 – Concluding remarks.

http://www.TheSignalPath.com
http://www.YouTube.com/TheSignalPath​​​
http://www.Patreon.com/TheSignalPath

TSP #228 – Teardown, Repair & Analysis of an Agilent 83752A 10MHz – 20GHz RF Synthesized Sweeper

In this episode Shahriar takes a close look at an HP 83752A which shows no signs of life. The power supply of the instrument does not produce standby or any other output voltages. The power supply is examined and the startup circuitry is at fault. The problem is traced to a bad startup capacitor for the primary PWM controller. A replacement resolves the issue and the instrument powers on.
The instrument however has other issues. An UNLOCK condition is displayed and further testing shows that the frequency output of the instrument below 2GHz is unstable. The overall block diagram of the unit is presented and the fault is logically traced to a potential problem with the reference 100MHz of the hetrodyne block. An X-Ray of the board allows us to reverse engineer the final output amplifier and a faulty NPN is located. A replacement resolves the UNLOCK condition and the instrument is fully functional.

http://www.TheSignalPath.com
http://www.YouTube.com/TheSignalPath​​​
http://www.Patreon.com/TheSignalPath

TSP #227 – Teardown & Repair of a Keysight U1253B 50,000 Count True RMS OLED Handheld Multimeter

In this episode Shahriar takes a look a Keysight U1253B multimeter with a notorious problem of failed OLED screens. The OLED would degrade and stop working on some of these units. Since the original OLED model is almost impossible to find, replacement OLED would require a protocol translation layer. The replacement module uses an FPGA to achieve this.

The teardown of the unit as well as the repaired units are shown. The performance of the instrument is verified using a universal source and an 8.5-digit multimeter.

http://www.TheSignalPath.com
http://www.YouTube.com/TheSignalPath​​​
http://www.Patreon.com/TheSignalPath