Archive for February 20, 2022

TSP #216 – Teardown & Repair of a Keithley 2001 7.5-Digit Multimeter

In this episode Shahriar repairs a Keithley 2001 7.5 Digit multimeter. This is a very high performance unit and worth repairing. However, the early 90's revision of these units were subject to electrolytic capacitor failure all overt the analog and digital boards. The failed capacitors destroy the nearby traces including the inner layer connections. The teardown of the unit reveals this problem. By using x-ray imaging the missing and damaged traces are identified and meticulously repaired. Several of the power supply diodes were also destroyed. The repaired unit passes all self-tests as well as measured V/I/R in both DC and AC correctly. The unit is compared with measurements reported by a Keithley DMM7510.

http://www.TheSignalPath.com
http://www.YouTube.com/TheSignalPath​​​
http://www.Patreon.com/TheSignalPath

TSP #215 – Teardown, Repair & Experiments with the Fluke 345 Digital Power Quality Clamp Meter

In this episode Shahriar repairs a Fluke 345 Digital Power Quality Clamp Meter. The Fluke 345 is more than an electric power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics.

Although the repair ends up being fairly simple, we get some insight into some of the user interface circuitry as well as some experiments showing the capabilities of the unit.

http://www.TheSignalPath.com
http://www.YouTube.com/TheSignalPath​​​
http://www.Patreon.com/TheSignalPath